Securing IPMI, iDRAC and iLO Print

  • 0

The out-of-band management controller (BMC) gives full control over a server: power, console and virtual media, even when the operating system is down. That makes it very useful, and very dangerous if exposed.

Rules we apply everywhere

  • Never put a BMC on the public internet. Use a separate management network, reachable only through a VPN or bastion host.
  • Change the default password on every controller, and use a unique one per server.
  • Update the firmware. BMCs have had serious vulnerabilities. Keep them current along with the BIOS.
  • Disable what you don't use, such as IPMI over LAN (UDP 623) if you only use the web interface or Redfish.
  • Create named accounts for each engineer instead of sharing the admin account, where the controller supports it.

Check from the command line

ipmitool lan print 1
ipmitool user list 1
ipmitool mc info

We set up and maintain out-of-band access as part of datacenter and server management.


Was this answer helpful?

« Back