A few hours of preparation saves many hours of trouble later. This is our checklist for every new server.
Hardware
- Update BIOS, BMC, RAID controller and NIC firmware before installing.
- Run a burn-in: memory test (memtest86+), a CPU stress test and disk tests, for at least 24 hours. Early failures show up here, not in production.
- Check SMART on every disk.
- Connect both power supplies to different feeds (A and B) and test pulling each one.
Configuration
- Set up RAID as planned and note which disk is in which bay with its serial number.
- Configure out-of-band access securely (see Securing IPMI, iDRAC and iLO).
- Set BIOS power profile for performance if needed, and enable restore-on-power-loss.
- Label the server and both ends of every cable.
Operating system
- Install updates, set the time zone and NTP, harden SSH.
- Add the server to monitoring and backups before it takes production traffic.
- Document it: role, IPs, location, RAID layout, who to contact.